2007 · 20 citations · 4 references
EngineeringElectrical EngineeringCircuit TheoryEnergy SystemsPower ElectronicsActive FiltersPower QualitySmall-signal AnalysisThree-phase CircuitsVoltage RegulationVoltage RegulatorsActive Harmonic FilteringActive Power FilterHarmonic ReductionHarmonicsLinear ControlLinear Control SystemsPower Quality ImprovementReactive Power Compensation
Current harmonics caused by nonlinear loads yield major power quality related problems in the utility. Such harmonics are commonly reduced by employing static compensators known as active power filters (APF). APF topologies are of various types, depending on technical and economical requirements; and their performance is intimately related to the applied control algorithm. In this paper, a new constant-frequency linear control scheme is proposed for a shunt three-phase four-leg APF. The APF is used to compensate the current distortion and the reactive power created by a typical industrial load. The elaboration of the control law is based on a small-signal averaged model of the converter, computed in the (d,q,0) synchronous frame. The control scheme consists of multiple-loops PI controllers that ensure voltage regulation at the DC side of the filter, and current wave shaping at the AC side. The control system is implemented numerically using the Matlab/Simulink tool. The performance of the proposed control approach is finally discussed through the obtained simulation results.
4
A series active power filter adopting hybrid control approach
Zhaoan Wang, Qun Wang, Weizheng Yao et al. · IEEE Transactions on Power Electronics · 2001 · 170 citations