Publication | Closed Access
In Ga As ∕ Al As Sb quantum cascade detectors operating in the near infrared
69
Citations
12
References
2007
Year
Short Wavelength OpticEngineeringQuantum SensingDetector PhysicsInfrared Optic∕ AlInstrumentationQuantum SciencePhotonicsRadiation DetectionPhysicsRoom TemperatureQuantum TechnologyInfrared SensorNatural SciencesSpectroscopyApplied PhysicsDetector PhysicSecond QcdDevice DetectsOptoelectronics
The authors report on short-wavelength In0.53Ga0.47As∕AlAs0.56Sb0.44 quantum cascade detectors (QCDs). At room temperature, one device detects at 505meV (2.46μm) with a responsivity of 2.57mA∕W, while a second QCD is sensitive at 580meV (2.14μm) with a responsivity of 0.32mA∕W.