Journal of Biomedical Materials Research · 1998 · 123 citations · 14 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryBiomechanicsOrthopedic BiomechanicsProstheticsArthroplasty BiomechanicsHip BiomechanicsJoint Replacement MaterialsMechanical TestingProsthetic MaterialsWear-resistant MaterialsMolecular OrientationProsthesis Wear MechanismsProsthetic Joint ReplacementWear MechanicsWear MechanismsWear Of Prosthetic MaterialsWear Rate MeasurementWear Testing
A realistic pin-on-disk wear test method for prosthetic joint materials has been developed. The new method, called circularly translating pin-on-disk (CTPOD), yields wear rates and wear mechanisms similar to those observed in retrieved polyethylene acetabular cups. In the established methods, where a polyethylene specimen slides against a unidirectionally rotating, or reciprocating, metallic or ceramic counterface, the wear rate typically is two orders of magnitude too low. In the present study, also, the reciprocator gave negligible wear. In the CTPOD method, considerable wear occurs because the direction of sliding rotates relative to the polyethylene pin, hence, the molecular orientation effect of polyethylene is avoided.
14
Encyclopedia of polymer science and engineering
C.S.H. Bawn · Polymer · 1987 · 4.2K citations
Natural Sciences, Materials Engineering, Materials Science +12
Orientation softening in the deformation and wear of ultra-high molecular weight polyethylene
A. Wang, D. C. Sun, Shi-Shen Yau et al. · Wear · 1997 · 210 citations
Natural Sciences, Materials Engineering, Materials Science +12