The Journal of the Acoustical Society of America · 1966 · 10 citations · 0 references
Natural SciencesPhysicsAcousticsUltrasonographyUltrasoundAcoustic RadiationAcoustic Wave PropagationPhysical AcousticsUltrasonicsUltrasound PhysicsEdge Pressure EffectsRadiation Field CharacterizationRadiation PatternsSound RadiationUltrasonic AcousticsUltrasonic Waves
A PZT-4 ceramic spherical segment with a radius of curvature of 30 cm has been used to produce a finite-amplitude ultrasonic field in water at a frequency of 2.2 Mcps. The field has been observed by a nonresonant probe with an active face of 18 in. diameter. The radiation field differs from that expected from an unbounded source since edge effects are present. This was noted for the low-amplitude case by A. O. Williams, Jr. [J. Acoust. Soc. Am. 17, 219–227 (1946)] and H. T. O'Neil [J. Acoust. Soc. Am. 21, 516–526 (1949)], who showed that the axial values of pressure amplitude from a spherical segment resembled those from a plane piston that is modulated by a reciprocal r term. Harmonic-radiation patterns for the fundamental component in the finite-amplitude case were found in general to be similar to those for the infinitesimal case, but differed somewhat in detail. The higher harmonic have also been measured both along the beam and transverse to it, and some interesting features have been noted. [Work supported by the U. S. Office of Naval Research.]