Anesthesia & Analgesia · 1999 · 69 citations · 9 references
Veterinary MedicineAnesthesiologyAnesthesiaAnesthetic TechniquesLocal AnesthesiaAnalgesiaAspiration RiskEpidural AnesthesiaGeneral Anesthetic AgentsAnesthetic Drug InfusionEpidural Catheter PlacementEpidural Test DoseIntravenous Bolus InjectionLabor Epidural AnalgesiaLabor Epidural PlacementLocal Anesthetic InfusionPharmacologic Labor Analgesia
UNLABELLED: Aspiration reliably detects almost all IV multiorifice epidural catheters. Although a supplemental epinephrine 15-microg test dose may detect the rare IV catheter that does not yield blood on aspiration, false-positive epinephrine responses may cause some women to unnecessarily undergo repeat epidural catheter insertion. We evaluated 532 consecutive eligible patients requesting neuraxial labor analgesia. Patients were excluded if they had a contraindication to epinephrine or if they received intrathecal sufentanil/bupivacaine. Multiorifice catheters were inserted 4-6 cm into the epidural space as part of an epidural (n = 305) or combined spinal-epidural (n = 270) technique. We used aspiration, a lidocaine/epinephrine test dose, and bolus injection or infusion of dilute bupivacaine/sufentanil solutions to systematically determine IV, intrathecal, or epidural catheter location. Aspiration alone detected 47 of 48 intravascular catheters. There were 10 positive epinephrine responses: 2 were true positives, 7 were falsely positive (subsequent local anesthetic injection/infusion produced bilateral sensory change and analgesia), and 1 catheter was removed without further testing. Aspiration detected almost all intravascular catheters. Although the epinephrine test dose did detect one catheter that proved to be in a blood vessel, 87.5% of positive responses occurred in women without intravascular catheters. IMPLICATIONS: Epidural catheters may enter a blood vessel. Many clinicians use epinephrine to detect these catheters. Because aspiration alone detects almost all IV multiorifice catheters in laboring women, a subsequent epinephrine test dose may be unnecessary.
9
The Components of an Effective Test Dose Prior to Epidural Block
Daniel C. Moore, Manbir S. Batra · Anesthesiology · 1981 · 243 citations · Full text
Limitations of Epinephrine as a Marker of Intravascular Injection in Laboring Women
Barbara L. Leighton, Mark C. Norris, Mitchel B. Sosis et al. · Anesthesiology · 1987 · 117 citations · Full text
Medicine, Gynecology, Obstetrics +11
Labor Epidural Analgesia without an Intravascular “Test Dose”
Mark C. Norris, Steven T. Fogel, Hiroko Dalman et al. · Anesthesiology · 1998 · 81 citations · Full text
Medicine, Anesthesiology, Obstetrics +14