Journal of Liquid Chromatography · 1995 · 10 citations · 14 references
PharmacyPharmaceutical AnalysisPharmacologyAnalytical ToxicologyChromatographic AnalysisMass Spectrometric AnalysisBioanalytical Method ValidationChromatographyLiquid ChromatographyAmphetamine DerivativesIllicit Drug DetectionLinear RangeMonoamine PharmacologyStimulant DetectionUrine Drug Screening
Abstract A relatively simple HPLC procedure used to detect and quantify amphetamine and 4′-hydroxyamphetamine in rat urine has been developed. Following Bond Elut[rgrave] solid phase extraction, the two analytes—amphetamine and 4′-hydroxyamphetamine, and the two internal standards—methamphetamine and 4′-hydroxymethamphetamine were separated by HPLC using a phenyl column and detected by UV at 215 nm. The limit of quantitation for amphetamine and 4′-hydroxyamphetamine was 0.92 and 0.81 μg/ml, respectively. Based on replicated analysis of controls at 1.6, 6.5, and 16.0 μg/ml, the method is accurate (94–103% of target), and precise (% CVs of 1.3–5.2). The linear range of the assay is suitable for the quantitation of both analytes at urine concentrations that commonly result from administration of a single dose of amphetamine to the rat.
14
The metabolic fate of amphetamine in man and other species
L. G. Dring, Robert L. Smith, R. T. Williams · Biochemical Journal · 1970 · 248 citations · Full text