Circulation Arrhythmia and Electrophysiology · 2010 · 123 citations · 13 references
MedicineCardiologySurgeryCardiothoracic SurgeryCardiovascular PharmacotherapyHemostasisAnticoagulant TherapyAnticoagulation ManagementAnticoagulation TherapyAntiplatelet TherapyAntithrombotic TherapyThrombosisAntiplatelet DrugsDevice Implantation CareDevice ThrombosisHeparin AnticoagulationHospital Stay DurationImplantable Cardioverter DefibrillatorsLate ComplicationsPermanent Pacemaker Therapy
BACKGROUND: Device implant pocket hematoma is a recognized complication after permanent pacemaker (PM) and implantable cardioverter-defibrillator (ICD) implantation. Pocket hematoma is associated with local discomfort, an increased risk of infection, and may require surgical intervention or lead to lengthier hospital stays. The purpose of the study was to identify the clinical factors associated with hematoma formation after PM or ICD device implantation. METHODS AND RESULTS: The subjects of this prospective observational study were 935 consecutive patients at Beaumont Hospital who underwent implantation of a PM or an ICD. Clinical characteristics and anticoagulant/antiplatelet drug use were recorded. A pocket hematoma was documented in 89 of 935 patients. Significant predictors of device pocket hematoma included ongoing clopidogrel therapy (18.3% on therapy, 10.5% recently discontinued, and 7.9% off therapy; P<0.001) and use of intravenous heparin (22.0% on therapy versus 8.2%; P<0.0001). Patients in whom clopidogrel was discontinued >4 days before device implantation had no hematoma. Hematomas occur more frequently in patients receiving ICDs than those receiving PMs. Device pocket hematoma was associated with an increased median length of hospital stay (4 days [interquartile range, 1 to 9] days with versus 2 days [ interquartile range, 1 to 6] days without hematoma; P=0.004) and increased late complications or surgical intervention. CONCLUSIONS: The use of clopidogrel or intravenous heparin significantly increased the risk of hematoma at the time of PM or ICD implantation. By withholding clopidogrel before surgery, the excess risk of bleeding complications may be reduced.
13
Atrial Fibrillation Ablation in Patients With Therapeutic International Normalized Ratio
Oussama M. Wazni, Salwa Beheiry, Tamer S. Fahmy et al. · Circulation · 2007 · 251 citations · Full text
Pocket Hematoma After Pacemaker or Implantable Cardioverter Defibrillator Surgery
Uwe Wiegand, D. Lejeune, F.H. Boguschewski et al. · CHEST Journal · 2004 · 223 citations
Medicine, Cardiology, Surgery +13
Sana M. Al‐Khatib, F. Lee Lucas, James G. Jollis et al. · Journal of the American College of Cardiology · 2005 · 192 citations