Materials ScienceThin Electrolyte FilmElectrical EngineeringElectrolyte Film ThicknessEngineeringCorrosion RatesElectrochemical Impedance SpectroscopyCorrosionCorrosion TechnologyCorrosion RateSurface ScienceCorrosion ProtectionCorrosion InhibitionElectrochemical InterfaceCorrosion ResistanceElectrochemistryElectrical Insulation
Electrochemical impedance spectroscopy (EIS) was applied to evaluate corrosion rates of steels covered with a thin electrolyte film. A two-electrode cell consisting of a pair of identical steel plates embedded in epoxy resin was used for the EIS measurements under the thin electrolyte film. A transmission line type equivalent circuit was employed to describe the EIS behavior. Using this method, a charge transfer resistance was successfully estimated under uneven current distributions. This technique was applied to estimate the corrosion rates of steels under electrolyte film thickness in a range of 5 μm to 1 mm.