EngineeringBiomedical EngineeringPhysiologyBioinstrumentationElectrophysiologyPhysiological Systems ModelingBiopotential MeasurementImpedance SpectroscopyMuscle MechanicsMuscle PhysiologyMuscle Signal ProcessingMuscle TissueBioimpedance MeasurementElectrical ImpedanceLeave-one-out AnalysisLeave-one-out Cross-validationMuscle Contractile FunctionMuscle Signal Feature ExtractionPrincipal Components
Four-electrode impedance spectra of relaxed and contracted muscle biceps brachii were analyzed in an adult human subject over the frequency range from 300 Hz to 75 kHz. A feasibility of the principal component analysis of bioimpedance measurement for the evaluation of skeletal muscle contractile state was examined. The principal components score plots show a data grouping of the impedance spectra from the two muscle groups. The classification was performed using a soft independent modeling of class analogy (SIMCA) method. The data set comprised 32 samples (16 samples of contracted muscle and 16 samples of relaxed muscle). The leave-one-out test of the classification yields about 80% of correctly classified samples (11 samples for contracted and 15 samples for relaxed muscle).
14
Measurement of muscle contraction with ultrasound imaging
Paul W. Hodges, Liset Pengel, Rob Herbert et al. · Muscle & Nerve · 2003 · 817 citations
Assessing neuromuscular disease with multifrequency electrical impedance myography
Gregory J. Esper, C. A. Shiffman, R. Aaron et al. · Muscle & Nerve · 2006 · 95 citations