Magnetic Resonance in Medicine · 1999 · 103 citations · 25 references
Life SciencesPhysiologyPulmonologyThoracic ImagingVentilationPulmonary PhysiologyRespiratory PhysiologyGuinea Pig ModelsImage Contrast OptimizationLongitudinal Relaxation TimePulse Sequence DesignRelaxation BehaviorRelaxation Time MeasurementsTransverse RelaxationTransverse Relaxation Time
The transverse relaxation time, T *(2), of hyperpolarized (HP) gas in the lung in vivo is an important parameter for pulse sequence optimization and image contrast. We obtained T *(2) maps of HP (3)He and (129)Xe in guinea pig lungs (n = 17) and in human lungs. Eight different sets of (3)He guinea pig studies were acquired, with variation of slice selection, tidal volume, and oxygen level. For example, for a (3)He tidal volume of 3 cm(3) and no slice selection, the average T *(2) in the trachea was 14.7 ms and 8.0 ms in the intrapulmonary airspaces. The equivalent (129)Xe experiment yielded an average T *(2) of 40.8 ms in the trachea and 18.5 ms in the intrapulmonary airspaces. The average (3)He T *(2) in the human intrapulmonary airspaces was 9.4 ms. The relaxation behavior was predicted by treating the lung as a porous medium, resulting in good agreement between estimated and measured T *(2) values in the intrapulmonary airspaces. Magn Reson Med 42:729-737, 1999.
25
The principles of nuclear magnetism
Nuclear Physics · 1961 · 4.1K citations
Biological magnetic resonance imaging using laser-polarized 129Xe
Mitchell S. Albert, G. D. Cates, Bastiaan Driehuys et al. · Nature · 1994 · 1K citations
Spin echo of spins diffusing in a bounded medium
C.H. Neuman · The Journal of Chemical Physics · 1974 · 428 citations · Full text