British Journal of Nursing · 2012 · 15 citations · 14 references
Health ProfessionsHealth AdministrationHealth PolicyGood Clinical PracticeInfection PreventionPatient SafetyCatheter-associated Infection PreventionGuideline ImplementationHealthcare-associated Infection PreventionInfection ManagementIntravenous Access DevicesStandard Of CareAccess Site Infection PreventionCare Bundle ImplementationGuidanceInfection Control MeasuresInfection Control PrecautionsIntravascular Catheter Infection PreventionPatient Outcomes MeasurementVascular Access Devices
Observed and audited variability in the insertion and care of vascular access devices (VADs), despite national guidance, led an intravascular (i.v.) team to develop seven basic standards under the mnemonic of HANDS. This initiative combined the Saving Lives guidance (Department of Health, 2007) with i.v. care bundles to reinforce best practice. The main reasons for the project were to decrease bacteraemia rates related to i.v. devices and to improve practice. The strategy of strengthening care bundling--Project HANDS--with a targeted education programme was adopted to ensure i.v. practice was consistent and evidence based. This project took a novel approach that evaluated the application of infection control measures, using i.v. device care as a tool to influence organisational change. This resulted in quality improvements and better patient outcomes. Further actions include disseminating the learning from this project to healthcare partners and in the community.
14
Issam Raad, William Costerton, U. Sabharwal et al. · The Journal of Infectious Diseases · 1993 · 552 citations