Neurosurgery · 2009 · 68 citations · 40 references
MedicineNeurosurgerySurgeryDiagnostic ImagingDiagnostic RadiologyNeuro-oncologyEndocrine Tumor SurgeryNeuro-oncologic SurgeryPituitary ImagingPituitary SurgeryPituitary TumorsTumor Resection TechniquesHigh-field Magnetic Resonance ImagingIntraoperative Magnetic Resonance ImagingLow-field Magnetic Resonance ImagingPituitary Macroadenoma ImagingPituitary Tumor ResectionPostoperative Residual Tumor AssessmentResection Of Residual TumorResidual Tumor Evaluation
OBJECTIVE: To evaluate the applicability of low-field intraoperative magnetic resonance imaging (iMRI) during transsphenoidal surgery of pituitary macroadenomas. METHODS: Fifty-five transsphenoidal surgeries were performed for macroadenomas (modified Hardy's Grade II-IV) resections. All of the surgical processes were guided by real-time updated contrast T1-weighted coronal and sagittal images, which were acquired with 0.15 Tesla PoleStar N20 iMRI (Medtronic Navigation, Louisville, CO). The definitive benefits as well as major drawbacks of low-field iMRI in transsphenoidal surgery were assessed with respect to intraoperative imaging, tumor resection control, comparison with early postoperative high-field magnetic resonance imaging, and follow-up outcomes. RESULTS: Intraoperative imaging revealed residual tumor and guided extended tumor resection in 17 of 55 cases. As a result, the percentage of gross total removal of macroadenomas increased from 58.2% to 83.6%. The accuracy of imaging evaluation of low-field iMRI was 81.8%, compared with early postoperative high-field MRI (Correlation coefficient, 0.677; P < 0.001). A significantly lower accuracy was identified with low-field iMRI in 6 cases with cavernous sinus invasion (33.3%) in contrast to the 87.8% found with other sites (Fisher's exact test, P < 0.001). CONCLUSION: The PoleStar N20 low-field iMRI navigation system is a promising tool for safe, minimally invasive, endonasal, transsphenoidal pituitary macroadenomas resection. It enables neurosurgeons to control the extent of tumor resection, particularly for suprasellar tumors, ensuring surgical accuracy and safety, and leading to a decreased likelihood of repeat surgeries. However, this technology is still not satisfying in estimating the amount of the parasellar residual tumor invading into cavernous sinus, given the false or uncertain images generated by low-field iMRI in this region, which are difficult to discriminate between tumor remnant and blood within the venous sinus.
40
Craniotomy for Tumor Treatment in an Intraoperative Magnetic Resonance Imaging Unit
Peter McL. Black, Eben Alexander, Claudia Martin et al. · Neurosurgery · 1999 · 304 citations
Medicine, Neurosurgery, Surgery +15
A mobile high-field magnetic resonance system for neurosurgery
Garnette R. Sutherland, Taro Kaibara, Deon Louw et al. · Journal of neurosurgery · 1999 · 261 citations
Medicine, Neurosurgery, Surgery +16
Intraoperative High-Field-Strength MR Imaging: Implementation and Experience in 200 Patients
Christopher Nimsky, Oliver Ganslandt, Boris von Keller et al. · Radiology · 2004 · 256 citations
Medicine, Neurosurgery, Surgery +17