Critical Care Medicine · 2002 · 101 citations · 18 references
Veterinary MedicinePhysiologySurgeryGastrointestinal Critical CareHemodynamic ManagementSmall Animal SurgeryHemodynamic SupportHemodynamicsHypoxia PhysiologyIntestinal IschemiaOxygen TherapyOxygen TransportBlood FlowCardiac IndexCritical Oxygen ConcentrationHypoxiaIschemic HypoxiaLactate ElevationMicrovascular Blood FlowOxygen Delivery
OBJECTIVE: To determine whether small intestine intramucosal PCO(2) and mucosal blood flow changes would be different between ischemic and hypoxic hypoxia. DESIGN: Randomized animal experiment. SETTING: Research laboratory. SUBJECTS: Anesthetized, mechanically ventilated, and surgically instrumented pigs. INTERVENTIONS: Systemic oxygen delivery was lowered in a stepwise manner to decrease it beyond critical oxygen delivery by lowering either FIO(2) or blood volume. MEASUREMENTS AND MAIN RESULTS: In hypoxic hypoxia pigs (n = 6), arterial oxygen concentration and oxygen delivery decreases were achieved by progressively reducing arterial PO(2) while cardiac index remained unchanged. In ischemic hypoxia pigs (n = 5), oxygen delivery reduction was achieved by progressively reducing cardiac index while arterial PO(2) remained unchanged. In control pigs, oxygen delivery remained unchanged. The lowest oxygen delivery measured in both hypoxia and ischemia experiments was 3.60 +/- 0.26 vs. 2.93 +/- 0.77 mL x kg(-1) x min(-1), respectively (p =.23). At the lowest oxygen delivery level, differences between ischemic hypoxia and hypoxic hypoxia experiments were observed for arterial lactate concentration (468 +/- 308 vs. 1070 +/- 218 mmol/L, respectively; p =.03), mixed venous arterial PCO(2) difference (10 +/- 7 vs. 4 +/- 2 torr, respectively; p =.04), and small intestine mucosal blood flow (6.2 +/- 2.1 vs. 15.7 +/- 7.4 perfusion units, respectively; p =.02). Small intestine intramucosal-arterial difference was higher in ischemic hypoxia than in hypoxic hypoxia (52 +/- 15 vs. 31 +/- 12 torr, respectively; p =.03). CONCLUSION: Small intestine intramucosal PCO(2) increases may indicate systemic oxygen uptake supply limitation in ischemic and hypoxic hypoxia related to conditions of mucosal flow stagnation and CO(2) generation.
18
Gastric intramucosal pH as a therapeutic index of tissue oxygenation in critically ill patients
Guillermo Gutiérrez, Fernando Pálizas, G.R Doglio et al. · The Lancet · 1992 · 866 citations
Medicine, Physiology, Surgery +13
Model for laser Doppler measurements of blood flow in tissue
R. F. Bonner, Ralph Nossal · Applied Optics · 1981 · 838 citations