Journal of Diabetes Science and Technology · 2010 · 55 citations · 19 references
MedicineEndocrinologyNutritionDiabetologyHuman NutritionMacronutrient MetabolismDiabetes ControlDiabetes ManagementDiabetes MellitusGlycemic ControlGlycemic MonitoringInsulin TherapyBlood Glucose RegulationBolus Insulin TherapyGlucose MonitoringGlucose Variability AssessmentGlucose-stimulated Insulin SecretionInsulin-regulated Glucose MetabolismSubcutaneous Drug AdministrationSubcutaneous Medication Administration
BACKGROUND: Estimation of the magnitude and duration of effects of carbohydrate (CHO) and subcutaneously administered insulin on blood glucose (BG) is required for improved BG regulation in people with type 1 diabetes mellitus (T1DM). The goal of this study was to quantify these effects in people with T1DM using a novel protocol. METHODS: The protocol duration was 8 hours: a 1-3 U subcutaneous (SC) insulin bolus was administered and a 25-g CHO meal was consumed, with these inputs separated by 3-5 hours. The DexCom SEVEN® PLUS continuous glucose monitor was used to obtain SC glucose measurements every 5 minutes and YSI 2300 Stat Plus was used to obtain intravenous glucose measurements every 15 minutes. RESULTS: The protocol was tested on 11 subjects at Sansum Diabetes Research Institute. The intersubject parameter coefficient of variation for the best identification method was 170%. The mean percentages of output variation explained by the bolus insulin and meal models were 68 and 69%, respectively, with root mean square error of 14 and 10 mg/dl, respectively. Relationships between the model parameters and clinical parameters were observed. CONCLUSION: Separation of insulin boluses and meals in time allowed unique identification of model parameters. The wide intersubject variation in parameters supports the notion that glucose-insulin models and thus insulin delivery algorithms for people with T1DM should be personalized. This experimental protocol could be used to refine estimates of the correction factor and the insulin-to-carbohydrate ratio used by people with T1DM.
19
G.S. Virk · Chemical Engineering Science · 1990 · 3.2K citations
Chemical & Engineering News · 1978 · 1.8K citations · Full text
Richard N. Bergman, Lawrence S. Phillips, Claudio Cobelli · Journal of Clinical Investigation · 1981 · 1.6K citations · Full text
Medicine, Endocrinology, Physiology +16
Evaluating Clinical Accuracy of Systems for Self-Monitoring of Blood Glucose
William L. Clarke, Daniel J. Cox, Linda Gonder‐Frederick et al. · Diabetes Care · 1987 · 1.4K citations
Medicine, Endocrinology, Biosensors +16