EngineeringBiotechnologyChemical EngineeringBiosensorsElectroanalytical MethodsElectrochemistryBiosensor DesignElectrochemical BiosensorsElectrochemical SensorsEnzyme-based BiosensorsAmperometric BiosensorsAmperometric Enzyme BiosensorsBiosensor CharacterizationElectrochemical BiosensingHydrogen Peroxide BiosensorsOxidative Stress DetectionRoom Temperature StabilitySensitivity
Amperometric biosensors for hydrogen peroxide were produced, based on TTF-modified graphite disc electrodes, incorporating immobilised peroxidase. At the optimum operating potential (−200 mV vs. calomel electrode), a linear response to hydrogen peroxide was obtained in the range 0–2 mM (Km value = 1.98 mM). Low sensitivity to pH fluctuations and good stability at room temperature were exhibited.