Explosion of thin aluminum foils in air

R. B. Baksht, A. Pokryvailo, Y. Yankelevich, I. Ziv

Journal of Applied Physics · 2004 · 17 citations · 13 references

Concepts

Abstract

An inductive-based power supply (240μH, 50kA) was used for the investigation of the foil explosion process in the time range of 0.05ms<texpl<0.2ms. The foil current for these experiments was set between 10kA and 27kA. The foil thickness was 10μm and its length was 5cm. Images of the exploding foil captured by a fast framing camera show that the radiation of the exploding foil discharge starts on the voltage rise. The peak voltage Vpeak decreases with an increasing time to explosion and a decreasing current density: Vpeak=2.8kV at j=9.1MA∕cm2 and Vpeak=1.75kV at j=5.3MA∕cm2. A phenomenological model was suggested for the experimental data interpretations. Contrary to the previous model, we assume that the breakdown initiates with cathode spots instead of a breakdown by a bulk discharge. We suggest that the plasma appearance is related to the ejection of a metal vapor during the metal boiling. The high temperature of the vapor permits ignition of the cathode spots even at a low electric field. It results in the arcing in the metal vapor and bypassing the liquid pieces of the foil.

References

13