Clinical Orthopaedics and Related Research · 2010 · 50 citations · 29 references
Natural SciencesOrthopaedic SurgeryOrthopedic SurgeryBiomaterialsOrthopaedic BiomaterialsPolymer MaterialsArthroplasty BiomechanicsBiodegradationPolymer ProcessingPolymeric BiomaterialsThermosetsThermosetting PolymersCrosslinked Polyethylene WearHighly Cross-linked PolyethyleneHighly Crosslinked PolyethyleneOxidationOxidative Degradation AnalysisPolyethylene ImplantsPolymer Degradation After SterilizationPolymer Sterilization
BACKGROUND: Highly crosslinked and thermally treated polyethylenes were clinically introduced to reduce wear and osteolysis. Although the crosslinking process improves the wear performance, it also introduces free radicals into the polymer that can subsequently oxidize. Thermal treatments have been implemented to reduce oxidation; however, the efficacy of these methods with regard to reducing in vivo oxidative degradation remains to be seen. Polyethylene oxidation is a concern because it can compromise the ultimate strength and ductility of the material. QUESTIONS/PURPOSES: We analyzed the oxidation, oxidation potential, and mechanical behavior of thermally treated highly crosslinked polyethylene retrieved acetabular liners. METHODS: Three hundred seven acetabular liners were collected from consecutive revision surgeries at six institutions over a 10-year period. Twenty-four were sterilized using nonionizing methods, 43 were sterilized in an inert environment, 80 were highly crosslinked and annealed, and 160 were highly crosslinked and remelted. Oxidation and oxidation potential were assessed by Fourier transmission infrared spectroscopy. Mechanical behavior was assessed by the small punch test. RESULTS: Oxidation and hydroperoxide (oxidation potential) indices were elevated in the annealed and gamma inert sterilized groups compared with those of the remelted liners and uncrosslinked gas sterilized controls, particularly at the rim. We also detected an increase in oxidation over time at the bearing surface of the remelted group. Ultimate strength of the polyethylene at the bearing surface was negatively correlated with implantation time for the annealed liners. CONCLUSIONS: Within the first decade of implantation, the clinical outlook for first-generation highly crosslinked polyethylene remains promising. However, ongoing research continues to be warranted for first-generation highly crosslinked polyethylene bearings to monitor the implications of elevated oxidation at the rim of annealed liners as well as to better understand the subtle changes in oxidation at the bearing surface of remelted liners that occur in vivo.
29
Orhun K. Muratoglu, C.R. Bragdon, Daniel O’Connor et al. · The Journal of Arthroplasty · 2001 · 640 citations
Natural Sciences, Materials Engineering, Materials Science +16
Impingement in Total Hip Arthroplasty
Won Yong Shon, Todd Baldini, Margaret G. E. Peterson et al. · The Journal of Arthroplasty · 2005 · 231 citations
Charles A. Engh, Adam Stepniewski, Stuart D. Ginn et al. · The Journal of Arthroplasty · 2006 · 210 citations