21st Fluid Dynamics, Plasma Dynamics and Lasers Conference · 1990 · 100 citations · 8 references
EngineeringAerospace EngineeringMechanical EngineeringAerodynamicsComputational Fluid DynamicsFluid DynamicsComputational AerodynamicsExperimental AerodynamicsFlow SeparationFlow StabilityTurbulenceTurbulent FlowFlow Separation ControlFrictional DragHelmholtz ResonatorsOil Flow VisualizationPressure RecoverySeparation ControlSeparation DelayStatic Pressure
Relative performance of several passive and active methods for controlling two-dimensional turbulent separated flow associated with a curved backward-facing ramp were investigated at low speeds. Surface static pressure measurement and oil flow visualization results indicate that submerged vortex generators, vortex generator jets, elongated arches at +-alpha, and large-eddy breakup devices at +-alpha placed near the baseline separation location reduce flow separation and increase pressure recovery. Spanwise cylinders reduce flow separation but decrease pressure recovery downstream. Arches with alpha = 0 deg, Helmholtz resonators, and Viets' fluidic flappers examined so far have no significant effect in reducing separation. Wall cooling computation indicates that separation delay on a partially cooled ramp is nearly the same as on a fully-cooled ramp while minimizing the frictional drag increase associated with the wall cooling process.
8