Health Physics · 2002 · 65 citations · 28 references
MedicineDental Public HealthRadiation DosimetryRadiation MeasurementRadiobiologyAbsorbed DoseRadiation Dose MeasurementRadiation HealthRadiation Risk AssessmentRadioactive DecayAbsorbed Dose ReconstructionBackground Radiation SubtractionEnvironmental Radiation DosimetryIonizing Radiation AssessmentNatural Background Radiation AssessmentNuclear FalloutRadiation Dose Assessment
Individual accumulated doses were determined by EPR spectroscopy of tooth enamel for 26 adult persons residing in territories adjacent to the Semipalatinsk Nuclear Test Site (SNTS). The absorbed dose values due to radiation from nuclear tests were obtained after subtracting the contribution of natural background radiation from the total accumulated dose. The determined dose values ranged up to 250 mGy, except for one person from Semipalatinsk city with a measured dose of 2.8 +/- 0.4 Gy. Increased dose values were determined for the individuals whose teeth were formed before 1962, the end of the atmospheric nuclear tests. These values were found to be significantly larger than those obtained for a group of younger residents of heavily exposed territories and the residents of territories not exposed to radioactive fallout. These increased dose values are consistent with those based on officially registered data for the Northeastern part of Kazakstan adjacent to SNTS, which was exposed to high levels of radioactive fallout from nuclear tests in period 1949-1962.
28
The second international intercomparison on EPR tooth dosimetry
A. Wieser, K. Mehta, S. Amira et al. · Radiation Measurements · 2000 · 112 citations
Nori Nakamura, C Miyazawa, Shozo Sawada et al. · International Journal of Radiation Biology · 1998 · 96 citations
Dental enamel as an in vivo radiation dosimeter
B. Pass, John E. Aldrich · Medical Physics · 1985 · 69 citations