Journal of Environmental Engineering · 2001 · 104 citations · 20 references
EngineeringEnvironmental EngineeringEnvironmental SciencesWaste ManagementWastewater TreatmentWater TreatmentAnaerobic DigestionChemical OxidationIndustrial Wastewater TreatmentNutrient RemovalWaste TreatmentWastewater BiotreatmentAnaerobic TreatmentChemical Oxygen DemandFenton ReactionFree Radical OxidationHydraulic Retention TimeLandfill Leachate TreatmentOrganic Load RemovalOrganic Loading Rate
The leachate from a Hong Kong landfill, containing 15,700 mg/L of chemical oxygen demand (COD) and 2,260 mg/L of ammonia nitrogen (NH3–N), was first treated in a UASB (upflow anaerobic sludge blanket) reactor at 37°C. The process on average removed 90.4% of COD with 6.6 days of hydraulic retention at an organic loading rate of 2.37 g of COD/L⋅day. The UASB effluent was further treated by the Fenton coagulation process using H2O2 and Fe2+. Under the optimal condition of 200 mg of H2O2/L and 300 mg of Fe2+/L and an initial pH of 6.0, 70% of residual COD in the UASB effluent was removed, of which 56% was removed by coagulation/precipitation and only 14% by free radical oxidation. It is obvious that H2O2 and Fe2+ had a strong synergistic effect on coagulation. The average COD in the final effluent was 447 mg/L. Removing each gram of COD required 0.28 g of Fe2+ and 0.18 g of H2O2.
20
George V. Buxton, C.L. Greenstock, W. Phillips Helman et al. · Journal of Physical and Chemical Reference Data · 1988 · 12.1K citations
Cheves Walling · Accounts of Chemical Research · 1975 · 2.8K citations
Pharmacy, Chemistry, Toxicology +6
Decolorizing dye wastewater with Fenton's reagent
Wen‐Guey Kuo · Water Research · 1992 · 692 citations
Engineering, Chemical Engineering, Environmental Engineering +12