Journal of Chemical Technology & Biotechnology · 2000 · 14 citations · 11 references
Life SciencesBiotechnologyMicrobiologyBiosensorsEnzymologyWastewater TreatmentBiological SensorsEnzymatic BiosensorsEnzyme AssaysEnzyme CharacterizationEnzyme-based BiosensorsMicrobial BiosensorsAmperometric SensingAmperometric SensorsBiochemical Oxygen DemandBiosensor DevelopmentEnzymatic HydrolysisEnzymatic Hydrolysis Of ProteinsEnzymatic SensorsEnzyme-based Sensors
A microbial amperometric sensor based on the yeast Arxula adeninivorans LS3 was tested for its suitability to measure the biochemical oxygen demand incurred by the use of high molecular weight substances, such as starch, cellulose and milk powder. As with other sensors, the untreated samples varied strongly from the corresponding BOD5. Digestion of macromolecules with α-amylase, cellulase and protease for 30 min at 37 °C resulted in sensor BOD values which correlated better with BOD5 values when corrected for the enzyme blank signal. © 2000 Society of Chemical Industry
11
Microbial electrode BOD sensors
Isao Karube, Tadashi Matsunaga, Satoshi Mitsuda et al. · Biotechnology and Bioengineering · 1977 · 359 citations
Matthias Lehmann, Kristina Tag, Maria Li Lung et al. · Biosensors and Bioelectronics · 1999 · 72 citations
Matthias Lehmann, Chiyui Chan, Anthony W.I. Lo et al. · Biosensors and Bioelectronics · 1999 · 56 citations
Monika Reiss, Andreas Heibges, Jutta Metzger et al. · Biosensors and Bioelectronics · 1998 · 47 citations
Engineering, Chemical Engineering, Environmental Engineering +8