Auger Electron Dosimetry

M.E. Wrenn, G. Howells, Leland M. Hairr, Anselmo Salles Paschoa

Health Physics · 1973 · 33 citations · 0 references

Concepts

Abstract

Calculations of radiation dose from nuclides which decay by electron capture have been conventionally performed by assuming that the resultant X-rays are absorbed in a “beta-like” fashion. However, Auger electron emission is more probable than X-ray emission for most elements of biological interest. The energy associated with the Auger process is conventionally included with the X-ray energy in calculations of dose (delta E/delta M). Since the range of an Auger electron is many times smaller than the mean free path of the equivalent X-ray, conventional calculations of dose may result in grossly inaccurate estimates whenever the dimensions of the biological object of interest is small compared to the mean free path of the X-ray. Since many elements are known to localize in subcellular structures (e.g. iron in ferritin aggregates) accurate dose calculations for electron capture nuclides are of great biological interest. Irradiation of biological systems with electron capture nuclides should provide a powerful tool to investigate radiation effects, and most particularly the adequacy of our present concepts of dose at the cellular and subcellular levels.