Virtual Neutral to Ground Voltage as Stability Index for Electric Arc Furnaces

Fernando Martell, Alejandro Deschamps, R.A Ramírez Mendoza, Miguel Meléndez, Armando Llamas, O. Micheloud

ISIJ International · 2011 · 19 citations · 4 references

DOIFull text

Open access

Concepts

Abstract

This article proposes an arc stability index for Electrical Arc Furnaces (EAF) based on the real-time processing of the line to ground three-phase voltage measurements typically available at the secondary side of the EAF's power transformer. This methodology uses the definition of a virtual neutral for the open delta connection to calculate the neutral to ground voltage waveform and its Root Mean Square value that can be considered in a simple formula as stability indicator of the arc itself and for the power delivery to the arc. This proposed stability indicator may be used for process monitoring and power control.

References