Degradation of PCBs by ferric ion, hydrogen peroxide and UV light

Joseph J. Pignatello, Guadalupe Chapa

Environmental Toxicology and Chemistry · 1994 · 72 citations · 17 references

Concepts

Abstract

Abstract A 1-g/L two-phase mixture of the commercial PCB oil Aroclor 1242 in acidified water at 66°C was degraded by a photoassisted Fenton-type reaction consisting of Fe3+, H2O2, and UV light (300-400 nm). Up to 88% PCB removal and 85% dechlorination were obtained, without attempts at optimization. The order of reactivity was di- > tri-> tetra- - – higher chlorinated biphenyls, but the selectivity was weak. Perfluorinated surfactants added to increase PCB solubility or rates of dissolution had a detrimental effect on degradation. Minimal reaction was observed at room temperature.

References

17