Samples of float glass were analyzed by Laser Ablation-Inductively Coupled Plasma-Mass Spectrometry (LA-ICP-MS) in order to develop an exclusion criterion for the discrimination of float glass sources based on elemental composition. Using a trace element menu consisting of Ti, Mn, Rb, Sr, Zr, Ba, La, Ce, Nd and Pb, 48 samples from a single float glass pane and 82 casework samples from different float glass sources were analyzed to assess Type I and Type II error rates by means of pairwise comparisons of element concentrations. A modified four standard deviation exclusion criterion, with minimum relative standard deviations of 4% or 5% per element, yielded the lowest Type I and Type II error rates of 0.27% and 0.11%, respectively. The use of LA-ICP-MS in combination with refractive index (RI) measurement provided complete discrimination of all of the 82 float glass samples.