Percutaneous pedicle screw placement in the thoracic spine: A cadaveric study
14
Citations
25
References
2013
Year
This cadaveric study shows that percutaneous pedicle screw placement can be performed in the thoracic spine without a significant increase in the pedicle breach rate as compared with standard open techniques. A small percentage (4.4%) of pedicles, especially high in the thoracic spine, may not be safely visualized.