Identification of Faceseal Leak Sites on a Half-Mask Respirator

Riedar K. Oestenstad, Jimmy L. Perkins, Vernon E. Rose

American Industrial Hygiene Association Journal · 1990 · 17 citations · 0 references

Concepts

Abstract

A method has been developed to identify the location and shape of respirator faceseal leak sites by the deposition of a fluorescent tracer. An aerosol generation, conditioning, and exposure system to provide a test environment with stable aerosol concentration and size distribution of 4-methyl-7-diethylaminocoumarin was designed and tested. Faceseal leak sites on a respirator mounted on a mannequin and worn by human subjects were identified by deposition of the tracer aerosol and subsequent observation under long-wave ultraviolet lighting. Test parameters were identified for the optimal definition of leaks. Photographic techniques were developed to document the identified leak sites.