IEEE Transactions on Instrumentation and Measurement · 1976 · 56 citations · 0 references
EngineeringElectrical EngineeringBridge EngineeringInstrumentationMicrowave EngineeringElectrical MeasurementImpedance MatchingMicrowave MeasurementsMicrowave Noise AnalysisMicrowave System DesignBridge CircuitsBridge Methods In Electrical MeasurementElectromagnetic Current MetersFour-terminal Resistance MeasurementImpedance MeasurementNew Instrument DesignPower MeasurementWheatstone Bridge Measurement
Problems intrinsic in self-balancing Wheatstone bridges have led to the development of a new dc substitution microwave power meter. The new instrument allows four-terminal measurement of bolometer resistance and affords improved accuracy and lower noise at a lower cost than earlier instruments. Measurement errors due to imperfect behavior of the servo system are typically less than 0.01 percent.