Journal of Geophysical Research Atmospheres · 1990 · 123 citations · 27 references
Natural SciencesGeophysicsPhysicsAtmospheric ElectricityElectromagnetismTime Series AnalysisLightning CurrentLightning PhysicsLightning PropagationThunderstorm DynamicsThunderstorm ElectricityThunderstorm ElectrificationLightning Current DerivativesLightning Current MeasurementLightning Current WaveformsRadiation Field MeasurementsReturn Stroke CurrentReturn Stroke DynamicsTransmission Line ModelingTransmission Line Theory
The study measured 40 simultaneous sub‑microsecond return‑stroke current, current derivative, and electric field derivative signals in Florida and France, then used the ratio of peak dE/dt to dI/dt, derived from a transmission line model, to compute return‑stroke velocities averaging 2.9–3.0×10^8 m/s, noting potential errors from near‑field contributions and multi‑wave structure. Peak return‑stroke currents ranged 5–50 kA, with peak dI/dt amplitudes 20–260 kA/µs, and mean peak dI/dt values were 2–3 times higher than tower measurements; dE/dt and dI/dt waveforms were linearly proportional and positively correlated with current, and the computed return‑stroke velocities (~2.9–3.0×10^8 m/s) were about twice optical estimates but may be over‑estimated due to near‑field effects and multi‑wave structure.
Forty simultaneous, submicrosecond time‐resolved measurements of triggered lightning returnstroke current ( I ), current derivative ( dI / dt ), and electric field derivative ( dE / dt ) were made in Florida and France in 1985 and 1986. Peak currents ranged from about 5 to 50 kA, peak dI / dt amplitudes from 60 to 260 kA/μs in 1985 and from 20 to 140 kA/μs in 1986. The mean peak dI / dt values, 111 kA/μs (1985) and 68 kA/μs (1986), are 2–3 times higher than data from instrumented towers, and peak I and dI / dt appear to be positively correlated. The dE / dt and dI / dt waveform pairs have similar shapes, and the peak amplitudes are linearly proportional. Return‐stroke velocity, computed from the ratio of peak dE / dt and dI / dt signal amplitudes using an expression derived from the radiation field term of the transmission line model (TLM), averaged 2.9×10 8 m/s and 3.0×10 8 m/s in 1985 and 1986, respectively, which is about 2 times higher than most optical measurements. The TLM velocity may be erroneous because (1) the dE / dt measurement was made only 50 m from the lightning channel, where fields other than the radiation field component, that is near fields, may contribute to the total dE / dt and (2) fine structure on the measured E fields was not consistent with a single upwardly propagating return‐stroke current wave assumed by the TLM (two waves are more consistent).
27
Lightning parameters for Engineering Application
R.B. Anderson · Electra · 1980 · 513 citations
Natural Sciences, Civil Engineering, Electrical Engineering +8