Journal of Clinical Pathology · 1961 · 43 citations · 0 references
Life SciencesBiochemistryAnalytical ChemistryCellular MetabolismMetabolismBioanalytical ChemistryBioanalytical Method ValidationCarbohydrate AnalysisCarbohydrate MetabolismEnzyme-based BiosensorsSugar AnalysisColorimetric Carbohydrate AssaysGlucose Analysis In Body FluidsGlucose BiosensorsGlucose Quantification
Current methods for the estimation of glucose concen- tration in body fluids using the Autoanalyzer employ non-specific colour reactions. We have therefore devised a procedure using glucose-oxidase which permits of the determination of true glucose concentrations with this instrument. Glycolysis is prevented by the addition of formalin. The reagents for each estimation cost approximately 1 id. REAGENTS 1 SODIUM ACETATE BUFFER 0-5M Add 40% sodium hydroxide to about 800 ml. distilled water containing approximately 30 ml. glacial acetic acid until the pH is