Isothermal flow of viscous liquids in corotating twin screw devices

M. L. Booy

Polymer Engineering and Science · 1980 · 119 citations · 2 references

Concepts

TL;DR

A mathematical model is derived for isothermal flow of a Newtonian liquid through corotating twin‑screw equipment. The model analyzes two flow regimes: fully filled channels that generate a pressure gradient and discharge pressure, and partially filled channels typical of extraction equipment, with equations for drag flow rate, pressure backflow, nip zone flow, and how fill degree varies with flow rate, speed, and dimensions. The analysis shows that single‑screw pump theory can be adapted to twin‑screw pumps.

Abstract

Abstract A mathematical model is derived for isothermal flow of a Newtonian liquid through corotating twin screw equipment. Two different flow regimes are studied. In the first, channels of twin screw equipment are completely filled with liquid, generate a pressure gradient, and provide a discharge pressure at the end of the pump. Equations are given for drag flow rate, pressure backflow rate, and flow rate through the nip zone. It is shown how the analysis of single screw pumps can be modified for twin‐screw pumps. In the second regime channels are partly full, which is the case with extraction equipment. Equations show how the degree of fill in the equipment changes with flow rate, speed, and dimensions.

References