Cloud-point curves of polymer solutions from thermooptical measurements

Young Chan Bae, Stephen M. Lambert, David S. Soane, John M. Prausnitz

Macromolecules · 1991 · 246 citations · 0 references

DOIFull text

Open access

Concepts

Abstract

Thermo-Optical Analysis (TOA) provides a simple, rapid and reliable experimental method to determine cloud-point curves of binary polymersolvent systems.Phase diagrams have been obtained for different molecular weights of polystyrene in cyclohexane, methyl acetate, ethyl acetate, and tbutyl acetate; and for poly(ethylene glycol) in water.Polystyrene solutions exhibit both upper and lower critical solution temperatures, while aqueous poly(ethylene glycol) solutions give closed-loop phase diagrams.The TOA apparatus described here uses very small samples (0.02 cm 3 ); for a binary system, upper and lower cloud-point curves can easily be obtained in about 8 hours.