Pulsed laser damage thresholds in vitro for intraocular lenses and membranes

S. K. Davi, D. Gaasterland, Claude E. Cummins, Gerard W. Liesegang

IEEE Journal of Quantum Electronics · 1984 · 14 citations · 11 references

Concepts

Abstract

Energy and power density damage thresholds were determined in air, for plastic IOL's and membranes at the focal point of several solid-state laser systems: 1) 694 nm, <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">Q</tex> -switched single pulse (30 ns), multimode, 2) 1064 nm, <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">Q</tex> -switched single pulse (20 ns), TEM <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">00</inf> , 3) 1060 nm, mode-locked single pulse, 15 ps, TEM <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">11</inf> , 4) 530 nm, mode-locked single pulse, 15 ps, TEM <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">11</inf> , and 5) 1064 nm, mode-locked pulse train (9-11 pulses, 30 ps), TEM <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">00</inf> . Pulse energies bracketing damage thresholds as well as focal diameter and pulse duration for each system were determined. Energy density thresholds are lower, and power density thresholds higher, for shorter duration pulses-e.g., 23 J/cm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> (1.15 GW/cm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> ) versus 6 J/cm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> (400 GW/cm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> ) at the same wavelength as in systems 2) and 3) (p = 0.005). Damage thresholds for glass IOL's are 37 J/cm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> (1.9 GW/cm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> ) and 37 J/cm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> (1235 GW/cm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> ) as in systems 2) and 5). Damage threshold values for plastic membranes (Saran Wrap <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">®</sup> ) exposed to nanosecond and picosecond pulse trains of Nd:YAG at 1064 nm are about half that of plastic IOL's. When laser pulses with a cone angle of 14° from systems 2) and 5) are focused on plastic membrane next to the IOL, damage thresholds are 30 J/cm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> (1.5 GW/cm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> ) for 20 ns <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">Q</tex> -switched pulses and 20 J/cm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> (670 GW/cm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> ) for trains of 30 ps mode-locked pulses. Damage thresholds of IOL's immersed in 0.9 percent saline are approximately the same as those obtained in air.

References

11