Concepedia

Publication | Closed Access

Dynamic Needle Tip Positioning – Ultrasound Guidance for Peripheral Vascular Access. A Randomized, Controlled and Blinded Study in Phantoms Performed by Ultrasound Novices

86

Citations

0

References

2012

Year

Abstract

The combined short axis and out-of-plane technique using dynamic needle tip positioning had a higher success rate and a shorter distance between the center of the target vessel and the needle tip compared to the combined long axis and in-plane technique.