Medicine · 2012 · 24 citations · 24 references
Veterinary MedicineCardiologyInfectious DiseasesClinical CardiologyInfectious Disease EpidemiologyMedical MicrobiologyBacterial InfectionsHealthcare-associated InfectionsImplant-associated InfectionMedical Device SafetyNosocomial Infection EpidemiologyNosocomial InfectionsCardiac Implantable DevicesCardiac Implantable Electronic Device InfectionCausative PathogensDevice-associated InfectionsDevice-related InfectionsPatient Financial Burden AnalysisStaphylococcal Implant InfectionStaphylococcal Infections Around Implants
Infections of cardiac implantable electronic devices (CIED) can cause significant morbidity, mortality, and financial burden. Although staphylococcal organisms account for most infections of these cardiac devices, approximately 20% of all CIED-related infections are caused by non-Staphylococcus species. Herein we describe and compare the demographics, clinical presentation, and outcomes of Staphylococcus aureus and non-staphylococcal infections of CIED. We performed a retrospective, multicenter, observational study of patients from 4 academic hospitals in Houston between 2002 and 2009. All 80 identified non-staphylococcal CIED-related infections were matched, at a 1:1 ratio, to S. aureus infections. Although the demographics and general comorbidities in the 2 study groups were relatively similar, the S. aureus group had a higher proportion of patients with coronary artery disease, diabetes mellitus, and end-stage renal disease. Additionally, 81% of S. aureus compared with only 48.5% of the non-staphylococcal CIED-related infections were health care-associated (p < 0.001). Furthermore, when compared to non-staphylococcal infections, the S. aureus group had more indwelling intravascular foreign material (p < 0.001), more rapid clinical progression (p < 0.001), and overall worse clinical presentation (p < 0.001). However, after stratifying by clinical presentation, the mortality rates in the 2 groups were similar (p = 0.45). Since approximately one-fifth of all CIED-related infections are caused by non-staphylococcal organisms, and untimely antibiotic treatment can result in serious complications, it may be prudent to broaden empiric antimicrobial therapy to cover both Gram-positive and -negative bacteria, until the causative organism is identified. Abbreviations CIED = cardiac implantable electronic devices, ESR = erythrocyte sedimentation rate, ICD = implantable cardioverter-defibrillators, MRSA = methicillin-resistant Staphylococcus aureus, MSSA = methicillin-sensitive Staphylococcus aureus, PPM = permanent pacemakers, TEE = transesophageal echocardiogram, TTE = transthoracic echocardiogram, WBC = white blood cell count
24
Ofelia C. Tablan, Larry J. Anderson, Richard E. Besser et al. · PsycEXTRA Dataset · 2004 · 1.3K citations
Health Professions, Infectious Disease Control, Infectious Diseases +17
Risk Factors Related to Infections of Implanted Pacemakers and Cardioverter-Defibrillators
Didier Klug, Mamadou Balde, Dominique Pavin et al. · Circulation · 2007 · 697 citations