Optimization of an Oxyfuel Combined Cycle Regarding Performance and Complexity Level

Adrian Dahlquist, Magnus Genrup, Mats Sjoedin, Klas Jonshagen

2013 · 22 citations · 2 references

Concepts

Abstract

The aim of this paper is to establish and motivate the design parameters of a 125 MW Oxyfuel Combined Cycle (OCC) also referred to as the Semi-Closed Oxyfuel-Combusted Combined Cycle (SCOC-CC). This paper proposes a compatible OCC that does not include any unconventional features, beyond what is state-of-the-art in gas turbine technology today. Such features could challenge the feasibility to bring the concept to the market in a reasonable time. The OCC requires a higher pressure ratio compared to a conventional combined cycle in order to achieve exhaust conditions that fit the design of the bottoming cycle. However, a high gas turbine pressure ratio increases the complexity of the machine and must be weighted against the gain in efficiency. The OCC gas turbine is modeled using a cooling model which keeps the metal temperature of all cooled turbine stages constant while seeking the optimum pressure ratio. As the cycle is semi-closed the compressor inlet temperature is a design parameter: it is shown that there is an efficiency optimum clearly in the range of what is normally achievable. As the gas properties of the OCC flue gas differ from the conventional plant, the effects of this on the HRSG design are explored.

References

2