Journal of Heat Transfer · 2010 · 43 citations · 23 references
Natural SciencesMaterials EngineeringMaterials ScienceHeat TransferSurface EngineeringSurface ScienceBoiling Heat TransferMetalsNanoporous MaterialsSurface PhysicsThin Film Thermal PropertiesBoilingBoiling On Structured SurfacesBoiling OnsetNucleate BoilingSaturationSurface TemperatureTemperature Excursion AnalysisTemperature Excursions
Experiments are performed to investigate saturation boiling of degassed PF-5060 dielectric liquid on microporous copper dendrite surface layers deposited on 10×10 mm2 Cu substrates. The electrochemically deposited surface layers are of different thicknesses (145.6 μm, 46.3 μm, and 33.1 μm). The thickest layer gives the best results: the saturation CHF of 25.27 W/cm2 occurs at a surface superheat of only 2.9 K and the maximum nucleate boiling heat transfer coefficient, hMNB, near the end of the fully developed nucleate boiling region, is 8.76 W/cm2 K. In addition, nucleate boiling ensues at a surface temperature slightly above saturation (<0.5 K), with no temperature excursion. The temperature excursions before initiating boiling on the 46.3 μm and 33.1 μm thick Cu nanodendrite surface layers are small (3.7 K and 6 K), corresponding to surface temperatures of ∼55.1°C and 57.4°C, respectively. These temperatures are much lower than recommended (85°C) for reliable operation of most silicon electronics and central processor units.
23
The Purposes of Uncertainty Analysis
S. J. Kline · Journal of Fluids Engineering · 1985 · 570 citations