Brazilian Journal of Medical and Biological Research · 2009 · 10 citations · 30 references
MedicineAnesthesiologySurgeryAnesthesiaObstetric AnesthesiaObstetric AnesthesiologyEpidural AnesthesiaNeonatal AnesthesiaObstetric Regional AnesthesiaThermoregulation During AnesthesiaApgar Score SurveillanceBody Core TemperatureCore Temperature ElevationGeneral Anesthesia EffectsNeonatal Apgar ScoresRectal Temperature MeasurementRectal Temperature Monitoring
Both epidural and general anesthesia can impair thermoregulatory mechanisms during surgery. However, there is lack of information about the effects of different methods of anesthesia on newborn temperature. The purpose of this study was to determine whether there are differences in newborn rectal temperature related to type of anesthesia. Sixty-three pregnant women were randomly assigned to receive general or epidural anesthesia. Maternal core temperature was measured three times with a rectal probe just before anesthesia, at the beginning of surgery and at delivery. In addition, umbilical vein blood was sampled for pH. The rectal temperatures of the babies were recorded immediately after delivery, and Apgar scores were determined 1, 5, and 10 min after birth. The duration of anesthesia and the volume of intravenous fluid given during the procedure (833 +/- 144 vs 420 +/- 215 mL) were significantly higher in the epidural group than in the general anesthesia group (P < 0.0001). Maternal rectal temperatures were not different in both groups at all measurements. In contrast, newborn rectal temperatures were lower in the epidural anesthesia group than in the general anesthesia group (37.4 +/- 0.3 vs 37.6 +/- 0.3 degrees C; P < 0.05) immediately after birth. Furthermore, the umbilical vein pH value (7.31 +/- 0.05 vs 7.33 +/- 0.01; P < 0.05) and Apgar scores at the 1st-min measurement (8.0 +/- 0.9 vs 8.5 +/- 0.7; P < 0.05) were lower in the epidural anesthesia group than in the general anesthesia group. Since epidural anesthesia requires more iv fluid infusion and a longer time for cesarean section, it involves a risk of a mild temperature reduction for the baby which, however, did not reach the limits of hypothermia.
30
Heat Flow and Distribution during Induction of General Anesthesia
Takashi Matsukawa, Daniel I. Sessler, Andrew M. Sessler et al. · Anesthesiology · 1995 · 555 citations · Full text
Heat Flow and Distribution during Epidural Anesthesia
Takashi Matsukawa, Daniel I. Sessler, Richard M. Christensen et al. · Anesthesiology · 1995 · 303 citations · Full text
Obstetric Anesthesia Work Force Survey, 1981 versus 1992
Joy L. Hawkins, Charles P. Gibbs, Miriam Orleans et al. · Anesthesiology · 1997 · 213 citations