Anesthesiology · 1996 · 53 citations · 17 references
Contrary to previous investigations in healthy patients, the current study demonstrates a high incidence of false-negative results when the SIB is used to confirm tracheal intubation in morbidly obese patients. If the SIB is used, the technique should include compression of the SIB after connection to the tube and should be used in conjunction with other clinical signs and technical aids. The mechanism of false-negative results in these patients seems to be related to reduction of caliber of airways secondary to a marked decrease in functional residual capacity, and collapse of large airways due to invagination of the posterior tracheal wall when sub-atmospheric pressure is generated by the SIB.
17
A Comparison of Pediatric and Adult Anesthesia Closed Malpractice Claims
Jeffrey P. Morray, Jeremy M. Geiduschek, Robert A. Caplan et al. · Anesthesiology · 1993 · 327 citations · Full text