The Journal of the Acoustical Society of America · 1992 · 381 citations · 14 references
EngineeringElectrical EngineeringMechatronics EngineeringBioinstrumentationInstrumentationMechatronicsArticulatory PhoneticsElectrical MeasurementElectrical SensorsTransducer TechnologyAlternating Magnetic FieldElectromagnetic ArticulographyElectromyographyMisalignment EffectsTransducers
Two commercially available midsagittal articulometer systems are briefly described for comparison. The study presents two electromagnetic midsagittal articulometer (EMMA) systems designed to transduce articulatory movements during speech production. The EMMA systems generate alternating magnetic fields with transmitter coils mounted on the speaker’s head, induce voltages in transducer coils attached to articulators, and process these signals to track articulator positions over time while correcting for rotational misalignment using either two transmitters with biaxial transducers or three transmitters with single‑axis transducers. Both systems yield useful midsagittal‑plane articulatory data, but with distinct advantages and limitations, and the three‑transmitter configuration is preferable when appropriate experimental controls are applied.
This paper describes two electromagnetic midsagittal articulometer (EMMA) systems that were developed for transducing articulatory movements during speech production. Alternating magnetic fields are generated by transmitter coils that are mounted in an assembly that fits on the head of a speaker. The fields induce alternating voltages in a number of small transducer coils that are attached to atriculators in the midline plane, inside and outside the vocal tract. The transducers are connected by fine lead wires to receiver electronics whose output voltages are processed to yield measures of transducer locations as a function of time. Measurement error can arise with this method, because as the articulators move and change shape, the transducers can undergo a varying amount of rotational misalignment with respect to the transmitter axes; both systems are designed to correct for transducer misalignment. For this purpose, one system uses two transmitters and biaxial transducers; the other uses three transmitters and single-axis transducers. The systems have been compared with one another in terms of their performance, human subjects compatibility, and ease of use. Both systems can produce useful midsagittal-plane data on articulator movement, and each one has a specific set of advantages and limitations. (Two commercially available systems are also described briefly for comparison purposes.) If appropriate experimental controls are used, the three-transmitter system is preferable for practical reasons.
14
Joseph S. Perkell, Melanie L. Matthies, Mario A. Svirsky et al. · The Journal of the Acoustical Society of America · 1993 · 156 citations