Cornea · 2008 · 133 citations · 17 references
MedicineOphthalmologySurgeryClinical Vision ScienceOphthalmic SurgeryRefractive SurgeryCorneal OpticsPostoperative Refractive OutcomesPreoperative Refractive EvaluationRefractive ErrorRefractive Error AssessmentIntracorneal Ring SegmentsKeratoconus SurgeryPostoperative Visual AcuityRefractive Cataract SurgerySpherical Equivalent RefractionUncorrected Visual AcuityVisual Acuity GainsVisual Acuity Improvement
PURPOSE: To evaluate the surgical outcomes of microthin intracorneal ring segment (INTACS) implantation in advanced keratoconus. METHODS: INTACS implantation was performed in eyes with advanced keratoconus. The main outcome measures were uncorrected visual acuity, best spectacle-corrected visual acuity, change in mean refractive spherical equivalent (MRSE), and keratometry. RESULTS: Intacs were implanted in 14 eyes with advanced keratoconus. At 6 months, uncorrected visual acuity improved from 0.05 +/- 0.08 to 0.16 +/- 0.11 (P < 0.05), and best spectacle-corrected visual acuity improved from 0.50 +/- 0.23 to 0.67 +/- 0.00 (P = 0.01). The spherical refractive error improved from -6.68 D +/- 6.44 to -3.11 D +/- 3.08 (P = 0.03), whereas the cylindrical refractive error improved from -4.89 D +/- 1.91 to -3.64 D +/- 1.27 (P = 0.04). The MRSE reduced from -9.13 D +/- 5.62 to -4.93 D +/- 3.19 (P = 0.01), and the average keratometry decreased from 53.01 D +/- 3.70 to 49.42 D +/- 3.79 (P < 0.05). The results were stable from 6 months to 1 year. The procedure showed 100% safety, and more than 60% tolerated contact lenses. Younger age, male sex, and minimum central pachymetry of more than 400 microm seemed to be associated with better outcomes. CONCLUSIONS: In this series, Intacs provided good results with respect to visual acuity, corneal topography, and MRSE in eyes with advanced keratoconus without major complications or the need for segment explanation. INTACS is potentially a safe and efficacious treatment option in the management of advanced keratoconus.
17
Correcting keratoconus with intracorneal rings
Joseph Colin, Béatrice Cochener, Gwenaelle Savary et al. · Journal of Cataract & Refractive Surgery · 2000 · 542 citations
Medicine, Ophthalmology, Surgery +16
Live-epikeratophakia for keratoconus
Jörg H Krumeich, Jan Daniël, A. Knülle · Journal of Cataract & Refractive Surgery · 1998 · 400 citations
Medicine, Ophthalmology, Surgery +15
Long-term Follow-up of Intacs in Keratoconus
George D. Kymionis, Charalambos S. Siganos, Nikolaos S. Tsiklis et al. · American Journal of Ophthalmology · 2006 · 225 citations
Medicine, Ophthalmology, Surgery +9