<title>Prototype CCD-based detector for whole-breast digital mammography</title>

D.R. Rosen, Walter C. Phillips, Martin Stanton, Juanhui Xie, Daniel M. O’Mara, Alexander Stewart

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · 1997 · 14 citations · 0 references

Concepts

Abstract

We describe a prototype multi-mode CCD-based detector for digital mammography. Each module incorporates a CCD bonded to a demagnifying fiberoptic taper. The x-ray-to-light converter is formed by depositing Gd<SUB>2</SUB>O<SUB>2</SUB>S:Eu onto the large end of the taper. The modules are held together in an array in order to cover a large area. We have constructed a 2-module prototype to evaluate the performance of this design and to develop software and hardware methods for the final multi-module detector. The 2-module detector forms an imaging area of 10 X 20 cm. with a 30-50 micrometers gap between the modules. Each module incorporates a 3.5:1 demagnifying fiberoptic taper and a 2048 X 2048, 14 micrometers -pixel CCD, resulting in an effective pixel size of 50 micrometers . For each 20keV x-ray photon incident on the phosphor converter approximately 7 electrons are generated in the CCD. For a 1 second exposure, the image noise is approximately 15 e/pixel and the dynamic range of the detector is approximately 20,000. The detector MTF is comparable to hat of a MinR screen/film system and the detector is able to resolve all features except the smallest spec group in an ACR phantom.