Cytometry Part A · 2008 · 21 citations · 5 references
Life SciencesCell BiologyImmunologyCellular ImmunologyClinical ImmunologyImmunology Of Infectious DiseasesCytokine BiologyFlow CytometryFlow Cytometric AnalysisFlow Cytometric Cell AnalysisFlow Cytometric Immune PhenotypingFlow Cytometric ImmunophenotypingFlow Cytometry ImmunophenotypingGating StrategiesMultiparameter Flow CytometryT-cell Immunogenicity
Intracellular cytokine staining (ICS) by multiparameter flow cytometry is one of the primary methods for determining T-cell immunogenicity in HIV-1 clinical vaccine trials. Data analysis requires considerable expertise and time. The amount of data is quickly increasing as more and larger trials are performed, and thus there is a critical need for high-throughput methods of data analysis. A web-based flow cytometric analysis system, LabKey Flow, was developed for the analyses of data from standardized ICS assays. Using a gating template created manually in commercially available flow cytometric analysis software, the system automatically compensates and analyzes all data sets. Quality control queries were designed to identify potentially incorrect sample collections. Comparison of the semiautomated analysis performed by LabKey Flow and the manual analysis performed using FlowJo software demonstrated excellent concordance (concordance correlation coefficient > 0.990). Manual inspection of the analyses performed by LabKey Flow for eight-color ICS data files from several clinical vaccine trials indicated that template gates can appropriately be used for most data sets. Thus, the semiautomated LabKey Flow analysis system can accurately analyze large ICS data files. Routine use of the system does not require specialized expertise. This high-throughput analysis will provide great utility for rapid evaluation of complex multiparameter flow cytometric measurements collected from large clinical trials.
5
A Concordance Correlation Coefficient to Evaluate Reproducibility
Biometrics · 1989 · 8.7K citations
Helen Horton, Evan P. Thomas, Jason Stucky et al. · Journal of Immunological Methods · 2007 · 254 citations · Full text
Quality assurance for polychromatic flow cytometry
Stephen P. Perfetto, David R. Ambrozak, Richard Nguyen et al. · Nature Protocols · 2006 · 197 citations
Peptide selection for human immunodeficiency virus type 1 CTL-based vaccine evaluation
Fusheng Li, Uma Malhotra, Peter B. Gilbert et al. · Vaccine · 2006 · 130 citations
Nina D. Russell, Michael G. Hudgens, Richard Ha et al. · The Journal of Infectious Diseases · 2003 · 118 citations · Full text