Journal of the Air & Waste Management Association · 2004 · 81 citations · 33 references
Natural SciencesChemistryEnvironmental SciencesAir PollutionAtmospheric ChemistryAtmospheric ScienceAir PollutantsAir Pollution MeasurementAir QualityAir SamplingNitrogen OxidesVolatile Organic CompoundsAmbient Air Quality MonitoringAmbient Voc MonitoringComparison Method ValidationNitrogen DioxideNitrogen Dioxide MeasurementNitrogen Oxides MeasurementPrecisionVolatile Organic Compound Sampling
This study evaluates the performance of Model 3300 Ogawa Passive Nitrogen Dioxide (NO 2 ) Samplers and 3M 3520 Organic Vapor Monitors (OVMs) by comparing integrated passive sampling concentrations to averaged hourly NO 2 and volatile organic compound (VOC) measurements at two sites in El Paso, TX.Sampling periods were three time intervals (3-day weekend, 4-day weekday, and 7-day weekly) for three consecutive weeks.OVM concentrations were corrected for ambient pressure to account for higher elevation.Precise results (5% relative standard deviation, RSD) were found for NO 2 measurements from collocated Ogawa samplers.Reproducibility was lower from duplicate OVMs for BTEX (benzene, toluene, ethylbenzene, and xylene isomers) VOCs (7% RSD for 2-day samples) with better precision for longer sampling periods.Comparison of Ogawa NO 2 samplers with chemiluminescence measurements averaged over the same time period suggested potential calibration problems with the chemiluminescence analyzer.For BTEX species, generally good agreement was obtained between OVMs and automated-gas chromatograph (auto-GC) measurements.The OVMs successfully tracked increasing levels of VOCs recorded by the auto-GCs.However, IMPLICATIONSComparison of passive OVMs with auto-GCs for VOCs and Ogawa badges with chemiluminescence analyzers for NO 2 are scarce.Regression analysis methods, correlation, concordance, and bias are used to evaluate collocated passive and continuous methods; the utility of duplicate sampling also is demonstrated.To account for the different number of samples collected between the reference and passive monitors, the present study employs an "adjusted t" statistic to better analyze the significance of the regression parameters.Finally, correction of passive sampler measurements under local ambient temperature and pressure conditions is emphasized, particularly for higher-elevation air sheds.
33
Technometrics · 2005 · 18.1K citations
Business, Biostatistics, Mathematics +17
A Concordance Correlation Coefficient to Evaluate Reproducibility
Biometrics · 1989 · 8.7K citations
Applied Regression Analysis and Other Multivariable Methods
Esteban Walker, David G. Kleinbaum, Lawrence L. Kupper et al. · Technometrics · 1989 · 8.4K citations