Publication | Open Access
Experimental Study of Microwave Pulse Compression Using a Five-Fold Helically Corrugated Waveguide
42
Citations
22
References
2015
Year
EngineeringRadio FrequencyEnergy EfficiencyMicrowave TransmissionAntennaMicrowave Pulse CompressionExperimental StudyComputational ElectromagneticsPulse PowerMicrowave Engineering
This paper presents the experimental study of microwave pulse compression using a five-fold helically corrugated waveguide. In the experiment, the maximum power compression ratio of 25.2 was achieved by compressing an input microwave pulse of 80-ns duration and 9.65-9.05-GHz frequency swept range into a 1.6-ns Gaussian-envelope pulse. For an average input power of 5.8 kW generated by a conventional traveling-wave tube, a peak pulse output power of 144.8 kW was measured corresponding to an energy efficiency of 66.3%.