Concepedia

Publication | Open Access

Three-dimensional time-averaged void fraction distribution measurement technique for BWR thermal hydraulic conditions using an X-ray CT system

15

Citations

9

References

2014

Year

Abstract

We have developed a void fraction distribution measurement technique using the three-dimensional (3D) time-averaged X-ray computed tomography (CT) system to understand two-phase flow behavior inside a fuel bundle for boiling water reactor (BWR) thermal hydraulic conditions of 7.2 MPa and 288 °C. As a first step, we measured the 3D void fraction distribution in a vertical square (5 × 5) rod array that simulated a BWR fuel bundle in the air–water test. A comparison of the volume-averaged void fractions evaluated by the developed X-ray CT system with those evaluated by a differential pressure transducer showed satisfactory agreement within a difference of 0.03. Thus, we confirmed that the developed system could be used to get 3D imaging of the vertical square rod array used in the test under the BWR operating pressure condition. In the next step, we did a verification test using the vertical pipe (11.3 mm ID) for BWR thermal hydraulic conditions. A comparison of the cross-sectional-averaged void fractions evaluated by the X-ray CT system with those evaluated by the drift-flux model showed good agreement within a difference of 0.05. We confirmed that the evaluated void fraction distribution forms in the horizontal cross section changed with the quality in response to the flow regime transition.

References

YearCitations