Thorax · 2001 · 76 citations · 32 references
Health ProfessionsClinical SciencesInternal MedicineExercise TestingPulmonary Function TestingPulmonologyFlow-volume LoopsForced Vital CapacityLung VolumesObstructive Lung DiseasePulmonary Function AssessmentPulmonary MechanicsChronic Obstructive Pulmonary Disease BronchodilationInspiratory Capacity AssessmentLung Mechanics AssessmentPulmonary Obstruction AssessmentSlow Vital CapacitySpirometric Lung VolumesSpirometric Reversibility IndicesTidal Breathing Assessment
BACKGROUND: Bronchodilator reversibility testing is recommended in all patients with chronic obstructive pulmonary disease (COPD) but does not predict improvements in breathlessness or exercise performance. Two alternative ways of assessing lung mechanics-measurement of end expiratory lung volume (EELV) using the inspiratory capacity manoeuvre and application of negative expiratory pressure (NEP) during tidal breathing to detect tidal airflow limitation-do relate to the degree of breathlessness in COPD. Their usefulness as end points in bronchodilator reversibility testing has not been examined. METHODS: We studied 20 patients with clinically stable COPD (mean age 69.9 (1.5) years, 15 men, forced expiratory volume in one second (FEV(1)) 29.5 (1.6)% predicted) with tidal flow limitation as assessed by their maximum flow-volume loop. Spirometric parameters, slow vital capacity (SVC), inspiratory capacity (IC), and NEP were measured seated, before and after nebulised saline, and at intervals after 5 mg nebulised salbutamol and 500 microg nebulised ipratropium bromide. The patients attended twice and the treatment order was randomised. RESULTS: Mean FEV(1), FVC, SVC, and IC were unchanged after saline but the degree of tidal flow limitation varied. FEV(1) improved significantly after salbutamol and ipratropium (0.11 (0.02) l and 0.09 (0.02) l, respectively) as did the other lung volumes with further significant increases after the combination. Tidal volume and mean expiratory flow increased significantly after all bronchodilators but breathlessness fell significantly only after the combination treatment. The initial NEP score was unrelated to subsequent changes in lung volume. CONCLUSIONS: NEP is not an appropriate measurement of acute bronchodilator responsiveness. Changes in IC were significantly larger than those in FEV(1) and may be more easily detected. However, our data showed no evidence for separation of "reversible" and "irreversible" groups whatever outcome measure was adopted.
32
Psychophysical bases of perceived exertion
Gunnar Borg · Medicine & Science in Sports & Exercise · 1982 · 16.4K citations
Lung volumes and forced ventilatory flows
PH Quanjer, G J Tammeling, J. E. Cotes et al. · European Respiratory Journal · 1993 · 5.3K citations · Full text
Quanjer Ph, Tammeling Gj, Cotes Je et al. · PubMed · 1993 · 3.8K citations
Health Professions, Clinical Sciences, Internal Medicine +17