Spine · 2005 · 152 citations · 36 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryPain ManagementPain MedicineSpine SurgeryFailed Back Surgery SyndromeNeurostimulationPain AssessmentPain MeasurementPain OutcomesSpinal Cord StimulationArray ElectrodesElectrical Stimulation ParametersElectrode DesignPsychophysical ThresholdsSpinal Cord Stimulation ComparisonSpinal Cord Stimulation DevicesStimulation CoverageStimulation Parameters
In Brief Study Design. A prospective, controlled, clinical trial comparing single and dual percutaneous electrodes in the treatment of axial low back pain from failed back surgery syndrome. Objectives. To clarify technical requirements and test the hypothesis that placing two linear arrays in parallel, thereby doubling the number of contacts, improves outcome. Summary of Background Data. Technical improvements have enhanced outcomes of spinal cord stimulation for chronic axial low back pain. Dual, parallel electrodes reportedly improve these outcomes. Methods. Acting as their own controls, 20 patients who passed screening with single, 4-contact electrodes received permanent dual, 4-contact electrodes with 7- or 10-mm intercontact distances at the same vertebral level(s). We quantified and compared the technical and clinical results of the single and dual electrodes, adjusting stimulation parameters to specific psychophysical thresholds. Results. Single electrodes provided significant (P < 0.01) advantages in patient- and computer-calculated ratings of pain coverage by paresthesias and in the scaled amplitude necessary to cover the low back, compared with dual 7-mm electrodes. Slight advantages without statistical significance were observed for the single over the dual 10-mm electrodes. Amplitude requirements were significantly lower for the single electrode than for either dual electrode. At long-term follow-up, 53% of patients met the criteria for clinical success. Conclusions. While we observed disadvantages for dual electrodes in treating axial low back pain, we achieved technical success with single or dual electrodes in most patients and maintained this success clinically with dual electrodes in 53%. This clinical trial of spinal cord stimulation compared use of single and dual percutaneous 4-contact electrodes to treat axial low back pain. The dual electrodes offered no advantage and in fact some disadvantages, but we achieved technical success with single and dual electrodes in most patients and maintained this success clinically in 53%.
36
The McGill Pain Questionnaire: Major properties and scoring methods
Ronald Melzack · Pain · 1975 · 6.9K citations
Nursing, Psychology, Pain Management +15
The measurement of clinical pain intensity: a comparison of six methods
Mark P. Jensen, Paul Karoly, Sanford Braver · Pain · 1986 · 3.3K citations
Nursing, Psychology, Pain Medicine +14
Studies with pain rating scales.
Walker Downie, P A Leatham, V M Rhind et al. · Annals of the Rheumatic Diseases · 1978 · 2K citations
Spinal cord stimulation for chronic, intractable pain: Superiority of “multi-channel” devices
Richard B. North, Matthew G. Ewend, Michael T. Lawton et al. · Pain · 1991 · 353 citations
Medicine, Neurosurgery, Surgery +10