Annals of Thoracic Medicine · 2012 · 42 citations · 13 references
MedicineOncologyRadiologyDiagnostic ImagingMetastasisUltrasonographyChest RadiologyLymph Node MetastasisLymph Node PathologyThoracic Oncology ImagingThoracic UltrasonographyUltrasound In OncologyBenign DiagnosisClinical Assessment Of LymphadenopathyDiagnostic Testing AccuracyLymph Node Assessment By UltrasoundLymph Node Metastasis AssessmentMalignant DiagnosisMediastinal Lymph Node MetastasisMediastinal Lymphadenopathy
OBJECTIVE: Newly arising enlarged or hypermetabolic mediastinal/hilar lymph nodes (LNs) in patients with previously diagnosed extrathoracic malignancies raise suspicion of metastasis. Relatively high proportion of these LNs is due to a benign condition. We aimed to determine frequency of malignant LNs and role of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) for clarification of the origin of suspicious LNs in these patients. METHODS: Consecutive patients with a known extrathoracic malignancy and suspected hilar/mediastinal LN were included in this prospective study. Computed tomography (CT) of thorax and positron emission tomography-CT of all patients were taken. LNs with short axis >1 cm at CT of thorax and SUV ≥ 2.5 were accepted suspicious for malignancy. All patients underwent EBUS-TBNA for pathological verification of LNs. Patients with benign diagnosis either underwent invasive procedures or were followed up. The results were evaluated for frequency of malignant hilar/mediastinal LNs and sensitivity, specificity, and diagnostic values of EBUS-TBNA. RESULTS: A total of 48 cases with a mean age of 57.4±11.6 were included. All cases had the diagnosis of an extrathoracic malignancy. 78 LNs were aspirated with EBUS-TBNA in 48 cases (1.62 LNs/patient). The mean short axis of aspirated LNs was 1.51±0.63. Results of EBUS-TBNA revealed malignancy in 15 cases (31.2%), tuberculosis in six cases (12.5%), sarcoidosis in four cases (8.3%), and reactive adenitis in 23 cases (48%). The sensitivity, specificity, and negative predictive value of EBUS-TBNA for malignancy were 83.3%, 100%, and 90.9%, respectively. When both benign and malignant diseases were considered, sensitivity, specificity, negative predictive value, and diagnostic accuracy of EBUS-TBNA were 89.2%, 100%, 86.9%, and 93.7%, respectively. CONCLUSIONS: The ratio of benign LNs in patients with extrathoracic malignancies is relatively high. EBUS-TBNA is a safe, minimally invasive, and effective method for clarification of intrathoracic LNs.
13
Regional Lymph Node Classification for Lung Cancer Staging
Clifton F. Mountain, Carolyn M. Dresler · CHEST Journal · 1997 · 1.4K citations
Endobronchial ultrasound guided transbronchial needle aspiration for staging of lung cancer
Kazuhiro Yasufuku, Masako Chiyo, Eitetsu Koh et al. · Lung Cancer · 2005 · 481 citations
Felix Herth, Ralf Eberhardt, Mark Krasnik et al. · CHEST Journal · 2008 · 380 citations