Comments on the optimization of high resolution Fabry-Pérot filtergraphs

G. B. Scharmer

Astronomy and Astrophysics · 2006 · 185 citations · 9 references

DOIFull text

Open access

Concepts

TL;DR

Image quality in telecentric Fabry‑Pérot interferometers is a key concern. The paper presents simulation results addressing image quality and the optimization of telecentric FPI systems with respect to cavity errors and transmission profile homogeneity. The authors model telecentric reimaging systems with two FPIs, analyzing how cavity errors affect the instrument function across the field of view. Simulations show that phase‑error‑induced image degradation can largely be compensated by refocusing, that pupil apodization is the main culprit, that high‑reflectivity dual‑FPI setups exhibit large profile variations unless cavity errors are below 2 nm, and that reducing the reflectivity of the FPI with the smallest cavity separation or using cavity ratios near 0.3 improves homogeneity at modest parasitic‑light cost.

Abstract

In this paper we present results of simulations of Fabry-Pérot (FPI) system performance that address two entirely separate aspects. The first concerns the image quality of FPIs used in telecentric optical setups. We show that the image degradation from phase errors found by von der Lühe & Kentischer (2000, A&AS, 146, 499) can largely be compensated by refocusing and that the major cause of image degradation is the pupil apodization discussed by Beckers (1998, A&AS, 120, 191). We also discuss the optimization of FPI systems, considering the effects of cavity errors on the homogeneity of the instrument function (transmission profile) across the FOV when two FPIs are combined in a telecentric reimaging system. Our conclusions from several numerical experiments are that telecentric FPI systems that use two or more FPIs with high (94–95%) reflectivities are likely to show large variations in the instrument profile across the FOV unless the cavity errors are significantly smaller than 2.0 nm. We show, that such homogeneity can be obtained at relatively low "cost" in terms of increased parasitic light levels by lowering the reflectivity of the FPI with the smallest cavity separation rather then lowering the reflectivity of both FPIs. We also demonstrate that the choice of cavity ratios has a strong impact on the homogeneity of the spectral transmission profile across the FOV and that double FPI systems with cavity ratios around 0.3 perform much better than at around 0.6.

References

9